  <entry>
    <title>Experience bias in structural design</title>
    <link href="https://smhelab.com/knowledge-center/experience-bias-structural-design/"/>
    <id>https://smhelab.com/knowledge-center/experience-bias-structural-design/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>Experience bias is the assumption that a product close to a previous success behaves the same. Small differences move stiffness, load path, and failure mode.</summary>
  </entry>
  <entry>
    <title>From test to FEA: how a backbone curve becomes a design input</title>
    <link href="https://smhelab.com/knowledge-center/backbone-curve-design-input/"/>
    <id>https://smhelab.com/knowledge-center/backbone-curve-design-input/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>The envelope of a connection’s cyclic load-deformation response replaces an assumed linear stiffness with measured behavior — initial stiffness, peak strength, and softening.</summary>
  </entry>
  <entry>
    <title>What a certification mark actually guarantees</title>
    <link href="https://smhelab.com/knowledge-center/what-a-certification-mark-guarantees/"/>
    <id>https://smhelab.com/knowledge-center/what-a-certification-mark-guarantees/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>A mark guarantees that specific claims about a specific scope were examined against evidence by an identified body, under a named standard — and nothing the scope does not state.</summary>
  </entry>
  <entry>
    <title>What Q ≈ 0.64 taught us about assuming efficiency factors</title>
    <link href="https://smhelab.com/knowledge-center/q-factor-0-64-efficiency-assumptions/"/>
    <id>https://smhelab.com/knowledge-center/q-factor-0-64-efficiency-assumptions/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>The industry assumed a stub-column efficiency factor of 0.90–0.95 for years. SMHE’s testing produced lower values, and independent European research reported Q ≈ 0.64 for a 3×3×14Ga section — roughly a third lower than assumed.</summary>
  </entry>
  <entry>
    <title>Consistent is not correct: why a repeatable test can be wrong</title>
    <link href="https://smhelab.com/knowledge-center/consistent-is-not-correct/"/>
    <id>https://smhelab.com/knowledge-center/consistent-is-not-correct/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>Precision means the result repeats; accuracy means it agrees with the reference the standard defines. A repeatable result from the wrong setup is precise and wrong.</summary>
  </entry>
  <entry>
    <title>The material certificate describes the coil, not the column</title>
    <link href="https://smhelab.com/knowledge-center/material-certificate-coil-not-column/"/>
    <id>https://smhelab.com/knowledge-center/material-certificate-coil-not-column/</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <author><name>Edward Choi</name><uri>https://smhelab.com/knowledge-center/authors/edward-choi/</uri></author>
    <summary>A mill certificate describes the coil as purchased. Roll-forming, punching, welding, and cold work can reduce ductility or narrow the yield-to-ultimate margin in the finished component.</summary>
  </entry>
  <entry>
    <title>From cyclic loops to a design input: Kconn and the backbone curve</title>
    <link href="https://smhelab.com/knowledge-center/testing-insights/"/>
    <id>https://smhelab.com/knowledge-center/testing-insights/#kconn-backbone-pipeline</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <summary>Rack connections are neither rigid nor pinned. Cyclic beam-to-column testing traces the hysteresis loops whose envelope — the backbone curve — carries the measured stiffness, peak, and softening an FEA model can actually use. Published notes on Kconn scatter and the backbone conversion are collected in Publications.</summary>
  </entry>
  <entry>
    <title>The efficiency factor everyone assumed — and where the number came from</title>
    <link href="https://smhelab.com/knowledge-center/testing-insights/"/>
    <id>https://smhelab.com/knowledge-center/testing-insights/#q-factor-third-lower</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <summary>The industry assumed a stub-column efficiency factor of 0.90–0.95 for years. SMHE’s testing produced lower values, and independent European research reported Q ≈ 0.64 for a 3×3×14Ga section — roughly a third lower than assumed. The full case study is in the Knowledge Center.</summary>
  </entry>
  <entry>
    <title>Are you testing the anchor — or the slab?</title>
    <link href="https://smhelab.com/knowledge-center/testing-insights/"/>
    <id>https://smhelab.com/knowledge-center/testing-insights/#anchor-or-slab</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <summary>An anchor pull test checks whether the anchor connection resists tension. A slab uplift test checks whether the slab resists uplift transferred through the anchorage pattern. A perfect anchor does not solve a weak slab — the first scoping step is deciding which question is being asked.</summary>
  </entry>
  <entry>
    <title>A torque check answers whether an anchor was tightened. A proof-load test answers whether it can resist load.</title>
    <link href="https://smhelab.com/knowledge-center/testing-insights/"/>
    <id>https://smhelab.com/knowledge-center/testing-insights/#torque-vs-proof-load</id>
    <updated>2026-07-10T00:00:00Z</updated>
    <summary>Two field checks that look adjacent and answer different questions. Torque verification confirms installation tightening; proof-load testing applies controlled tension and measures resistance. Specifying one when the concern calls for the other leaves the actual assumption unexamined.</summary>
  </entry>