About · Our story
Built from the work.
SMHE Lab developed out of engineering work in the material handling industry. That work raised questions a calculation could not settle, and the laboratory grew from the fixtures, instruments and procedures built to answer them. This is the story of how that approach to testing developed — and where it is heading.
Before there was a laboratory
The questions came first.
The work began within Seizmic’s material handling engineering practice: analysing storage rack systems, building tools that made that analysis repeatable, and producing load tables for manufacturers.
Testing was part of that practice from early on, but for years it was occasional work alongside the engineering. Ed Choi joined the engineering staff in 2000 and, during those years, ran tests, processed the data and prepared initial reports.
The analysis rested on values few people had measured for themselves: how stiff a connection really is, how much strength a perforated column keeps, and what the steel delivers rather than what it was specified to deliver. The standards provide methods for obtaining such values by test. In practice, many of the values in use had been inherited.
An engineer who relies on a number should be able to say where it came from. Testing became the practical way to answer that. In those years the testing itself was largely analog: readings were often taken by hand and charted manually, and much of the control of a test depended on the person running it.
Building what didn’t exist
From a test requirement to a working system.
Cyclic beam-to-column connection testing required repeated reversal of load while force and displacement were measured and controlled. Performing that work manually was technically possible, but it was not a practical foundation for repeatable testing.
The immediate problem was equipment. SMHE could not find a suitable off-the-shelf bidirectional motor-control solution for the system it needed, so the system was developed in-house: Ed Choi designed the control circuitry and instrumentation and wrote the data-acquisition software. By 2012, that work had become the foundation for more controlled, repeatable and automated cyclic testing at SMHE.
Fixtures and frames were added as programs required them, and records began to move from paper into structured files, so that a result could be traced back to its specimen, its setup and its data.
The lasting product of this period was not any single rig. It was a pattern: a repetitive engineering problem was first solved by hand, repetition showed what could be systematized, and a purpose-built system followed. That pattern would repeat.
Writing the system down
From practice to a system others can assess.
Practical knowledge became written process. Written process became a controlled laboratory system. That system was then independently assessed, and it has kept maturing since.
- Early periodPractical knowledge
- 2016Written process
- 2018Independent assessment
- 2020System matures
- OngoingContinuous improvement
For years, much of what made a result reliable lived in practice: in how a test was set up, how an instrument was read, how a result was checked. In June 2016 the laboratory was approved as a testing agency by the Los Angeles Department of Building and Safety, and that approval required practice to be written down as controlled procedure. A procedure had to say what was actually done, a record had to show it, and anything that could not be shown had to be put right. LADBS approval concerns the testing agency; it is not an ISO/IEC 17025 accreditation.
The next step was independent assessment against the international framework for testing laboratories. In January 2018, the International Accreditation Service (IAS) assessed the laboratory against ISO/IEC 17025:2005. Ed Choi, who had led the drafting of the quality-system documentation prepared for it, served as the laboratory’s Technical Manager and technical contact for that assessment and coordinated the laboratory’s responses to its findings. The laboratory’s ISO/IEC 17025 accreditation, TL-732, took effect in March 2018.
An assessment does not end with a certificate. Findings become corrective actions, corrective actions become revised procedures, and the revised procedure is what the next test follows. When ISO/IEC 17025 was published in a new edition, the laboratory restructured its system to match, and IAS assessed it against ISO/IEC 17025:2017 in September 2020. It was the same system, matured, rather than a new badge. Ed Choi remained Technical Manager through that assessment, later served as Quality/Technical Manager, and has been Lab Director since 2025. The documentation has continued to grow since, with contributions from across the laboratory.
By early 2021, S-Mark had distinct identities for testing and for inspection: complementary forms of conformity assessment that went on to develop along separate paths. The laboratory’s testing work used the testing-side identity. SMHE Certified carries that testing lineage forward, directly under the SMHE name.

Testing identity, circa 2021
SMHE laboratory identity
IAS Accredited Testing Laboratory — TL-732 · ISO/IEC 17025:2017
Formal accreditation applies to the activities identified in SMHE’s published Scope of Accreditation. View current IAS scope
When the specimen disagreed
When the specimen disagreed.
For years, rack design carried a familiar pair of numbers. A perforated 14-gauge column was expected to deliver a stub-column efficiency, Q, of about 0.90; a 13-gauge column, about 0.95.
Q accounts for what a perforated, cold-formed section loses to its holes and thin walls, and it flows directly into column capacity. When SMHE’s stub-column tests began producing values that did not consistently fit those expectations, the unexpected results prompted additional testing and investigation.
An independent European research laboratory reported Q ≈ 0.64 for a 3×3×14Ga section — roughly a third below the familiar assumption. That work came to SMHE’s attention later. It did not start the inquiry; it gave the behavior SMHE had already been seeing an independent point of comparison.
Independent research
Q ≈ 0.64
Corroborating evidence, not a value to assume.
The work that followed was about why the numbers differed: tested versus nominal yield strength, coil strip versus finished-product properties, the effect of cold work, net-area conventions, differences between editions of the specification, and how a test-derived Q should relate to the Q used in design.
The significance of 0.64 is not that it should become the next number to assume. Replacing one inherited value with another would repeat the original mistake. What it reinforced was a question that now applies to every consequential number in a design:
Where did this number come from?
The same question later reached material properties, stub-column behavior, connection stiffness and other component-level inputs. It is why SMHE describes each test by the assumption it checks, and by what it does not prove. Read the Q ≈ 0.64 case study
Beyond racks
Not every capability became a line of work.
The equipment and methods that answer rack questions can answer others, and over the years the laboratory has been asked to. Some of that work was exploratory, a way of learning what the laboratory could do. Some proved to be a genuine extension of its field. Material handling remains the centre of the work, and it is the second kind of work that shapes what SMHE offers beyond it.
Walkable ceiling grids show the kind of question that carries over. In evaluations of that kind the governing limit can be serviceability rather than strength: a deflection limit such as L/360 can set the effective rating. The number that governs is not always the one the specification emphasises.
From result to design input
From result to design input.
A test can answer whether a product held. Increasingly, the more useful question is what value an engineer should use.
Material is the plainest case. Coupons taken from finished parts measure the steel as delivered, after forming, rather than as specified, and that measured strength is what a test-derived Q depends on.
Connections are a second case. Beam-to-column connections in rack frames are semi-rigid, and ANSI MH16.1-2023 §13.5.5 sets out how their stiffness, Kconn, is obtained by test. The test’s full moment–rotation response, the backbone curve, holds more than a single stiffness value and can serve as an input to nonlinear analysis. As test methods mature, more of what is measured can be translated into reusable engineering inputs rather than remaining only as reported test results.
In each case the laboratory reports what was measured and how. Choosing design values from those results remains the work of a qualified engineer for the intended application.
What repetition teaches
The same questions, asked many times.
Across the industry, manufacturers ask many of the same questions of their products: how a connection behaves, what a column section actually carries, how a base holds. Each answer has to be obtained by test.
When that testing happens separately, inside each company, the knowledge of how to obtain those answers well tends to stay where it was learned. An ISO/IEC 17025 laboratory focused on one industry meets related questions again and again, across many testing programs. What it retains from that repetition is not anyone’s product information or results. It is how reliable evidence is obtained.
Stays with each client
Results, reports, and product and design information. They remain confidential to the client who commissioned the work; they are not pooled, generalized or published.
Accumulates in the testing process
- Better fixtures and specimen restraint
- Better instrumentation, setup and measurement discipline
- More mature procedures and method interpretation
- Familiarity with the component questions that recur
- Less variation between operators and setups
The details matter more than they appear to. A beam-to-column connection test set up slightly differently from the arrangement the standard defines can produce results that are consistent, and consistently away from the reference. Repetition is how those details are found and fixed.
Each repetition refines the procedure. A refined procedure is more repeatable. A repeatable procedure leaves less room for variation between operators, setups and laboratories. Testing that varies less can be streamlined without losing what makes it defensible, and part of that discipline is knowing how much precision a given question actually needs.
The effect reaches past the laboratory. When component-level evidence can be obtained consistently, engineers spend less effort re-establishing it, and more of their judgment goes where it adds the most value: to the application and the system.
- Repeated testing→
- Specialization→
- Refined procedure→
- Repeatability→
- Less variation→
- Judgment at the system level
Standardize what can be standardized, so engineering judgment can remain focused where judgment adds the most value.
The road ahead
Knowledge becomes method.
For much of this history, the pieces developed separately, each for its own reason. Their value comes from working together.
Instrumentation made physical evidence possible. Testing-agency approval turned practice into written process, and ISO/IEC 17025 made that process something others could assess. Meeting related questions across the industry, again and again, refined the procedural knowledge of how reliable answers are obtained, and showed which parts of the work could legitimately be standardized.
Records followed the same pattern as everything else on this page: handwritten readings gave way to instrumented test systems and structured digital records, kept in record-keeping tools Ed Choi developed for the laboratory, and automation serves the same ends of traceability and repeatability. Technical communication carries what is learned beyond the laboratory.
Today
Accumulated testing knowledge becoming repeatable institutional method.
What the laboratory learns from each program about fixtures, setup, measurement and method interpretation is written into procedure, so the next test starts from it rather than from scratch.
Ahead
The opportunity is larger than making individual tests more efficient. When recurring technical questions are converted into repeatable methods, documented evidence and reusable engineering inputs, the work already done can help reduce the work that has to be done again.
That is the idea behind collaborative paving: work through difficult technical ground carefully, document what can be shared, and leave a clearer path for those who follow. What is shared is method — procedures, practices and an understanding of the questions that recur. Each client’s results remain that client’s own.
Industry alignment extends that idea. Better alignment between testing, repeatable procedures, engineering methods, evaluation and the inputs used for design can reduce duplicated effort, while preserving the engineering judgment each application needs.
- Collaborative paving
- Industry alignment
- Shared industry efficiency
SMHE Certified represents one possible next step in that direction: connecting testing, documented evidence and engineering evaluation into a more repeatable framework for demonstrating what has been established. It is a step in the direction shown here, not the destination.
The objective is not to predetermine the next landmark. It is to keep moving toward an industry where better evidence leads to less repeated effort, better engineering decisions and greater shared efficiency.
Early period
Analog and basic instrumentation
2012
Advanced instrumentation
2016
Approval: LADBS testing agency
2018
ISO/IEC 17025:2005
2020
ISO/IEC 17025:2017
c. 2021
S-Mark testing identity
Today
Accumulated testing knowledge becoming repeatable institutional method
Documented landmarks
Ahead · unnamed
Early period
Analog and basic instrumentation
2012
Advanced instrumentation
2016
Approval: LADBS testing agency
2018
ISO/IEC 17025:2005
2020
ISO/IEC 17025:2017
c. 2021
S-Mark testing identity
Today
Accumulated testing knowledge becoming repeatable institutional method
The direction is visible. The destination is not predetermined.
Start a conversation.
Bring the question your calculation can’t settle.