Skip to content
IAS TL-732LADBS TA24846
SMHE Lab

Knowledge Center · Live

What the lab is learning, as it learns it.

Testing insights and technical notes — each entry tied to the assumption it examines and the decision it supports. Testing turns assumptions into evidence; this is where the evidence surfaces first.

Answer

This feed carries only public material: educational distinctions and published notes.

Recent entries

Feed entries

Testing insight

A torque check answers whether an anchor was tightened. A proof-load test answers whether it can resist load.

Two field checks that look adjacent and answer different questions. Torque verification confirms installation tightening; proof-load testing applies controlled tension and measures resistance. Specifying one when the concern calls for the other leaves the actual assumption unexamined.

Assumption examined · The installed anchorage can resist the tension demand assumed in the design.

Anchor Torque VerificationAnchor Proof-Load Testing

Testing insight

Are you testing the anchor — or the slab?

An anchor pull test checks whether the anchor connection resists tension. A slab uplift test checks whether the slab resists uplift transferred through the anchorage pattern. A perfect anchor does not solve a weak slab — the first scoping step is deciding which question is being asked.

Assumption examined · The slab system can resist the uplift demand the rack design transfers into it.

Anchor Proof-Load TestingSlab Uplift Proof-Load Testing

Testing insight

The efficiency factor everyone assumed — and where the number came from

The industry assumed a stub-column efficiency factor of 0.90–0.95 for years. SMHE’s testing produced lower values, and independent European research reported Q ≈ 0.64 for a 3×3×14Ga section — roughly a third lower than assumed. The full case study is in the Knowledge Center.

Assumption examined · An inherited section-efficiency factor applies to the section being designed, without re-examining the basis it came from.

Stub Column Testing

Testing insight

From cyclic loops to a design input: Kconn and the backbone curve

Rack connections are neither rigid nor pinned. Cyclic beam-to-column testing traces the hysteresis loops whose envelope — the backbone curve — carries the measured stiffness, peak, and softening an FEA model can actually use. Published notes on Kconn scatter and the backbone conversion are collected in Publications.

Assumption examined · The connection stiffness assumed in the frame model matches the finished connection’s measured behavior.

Beam-to-Column Cyclic TestingColumn Base Fixity Testing

How this feed works

Why does SMHE Lab keep a feed?

Answer

Because assumptions age quietly, the evidence base has to keep growing. Every entry answers the same questions: what assumption is being checked, and what decision does the evidence support.

Deeper material lives in the Knowledge Center pillars, the publications archive, and the test types library.

Did one of these entries name your uncertainty?

That’s the feed doing its job. Tell us what you make and what changed — we’ll scope the test that turns the assumption into evidence.

Request testing