Skip to content
IAS TL-732LADBS TA24846
SMHE Lab

Knowledge Center · Publications

Published, because examined openly is stronger.

An assumption examined once by one lab helps no one; an assumption examined openly strengthens the whole industry. This is the running archive of SMHE technical publications.

Answer

SMHE Lab publishes technical notes on the assumptions behind rack engineering — connection stiffness, stub-column efficiency, base fixity, slab behavior, loading protocols, and what certification actually guarantees.

The publications listed here were written by and first published on LinkedIn on the dates shown. Each has a permanent record on this site, with a link to the original.

Articles & explainers

Long-form publications

  • Article · · Edward Choi

    Why L/360 Matters for Ceiling Grids (and Why Strength Isn't the Limiting Factor)

    Explains why walkable and structural ceiling grid ratings are often governed by the L/360 serviceability limit rather than strength, grounds the limit in ASTM E3090/C635/E580 context, and draws a lesson from a recent evaluation where deflection, not yielding, set the rating — pointing to stiffness-driven design changes.

    Assumption examined · Strength, rather than serviceability, governs the load rating of walkable and structural ceiling grid systems.

    Original on LinkedIn

  • Article · · Edward Choi

    How to Read a Mill Certificate

    Reads a mill certificate the way a plan checker or reviewer does: as a traceability document rather than a materials report. Lists what reviewers look for — the issuing mill, the heat or batch number, and a link from the certificate to the component — and the gaps that break the chain of accountability even when the reported values look clean.

    Assumption examined · That a mill certificate with acceptable chemistry and strength values is, by itself, sufficient evidence for the installed component.

    Original on LinkedIn

  • Article · · Edward Choi

    Imported Components & Accountability: Why Strong Manufacturers Treat U.S. Verification as a QA Layer

    Argues that manufacturers supplying components into U.S. projects should treat U.S.-based material verification — periodic sampling tied to mill certificates, tested by an accredited laboratory — as a routine QA layer that establishes external traceability and keeps submittals moving when documentation is scrutinized.

    Assumption examined · A mill certificate by itself constitutes recognized, traceable evidence of material properties for components entering U.S. projects.

    Original on LinkedIn

  • Article · · Edward Choi

    From Kconn to Backbone Curves: Why Connection Testing Is Quietly Entering Its Next Phase

    Observes rising demand for ANSI MH16.1-2023 Section 13.5.5 evaluations and argues Kconn is necessary but not sufficient for engineers moving into nonlinear FEA, who need backbone curves and hysteretic models extracted from cyclic test data — an optional engineering output the lab is building workflows to provide.

    Assumption examined · A single Kconn stiffness value is a sufficient connection input for nonlinear finite element analysis.

    Original on LinkedIn

  • Article · · Edward Choi

    Rethinking Base Fixity Tests in Steel Storage Racks

    Reframes base fixity testing as bounding uncertainty in an inherently semi-rigid, configuration-dependent connection rather than measuring an exact stiffness, arguing the most valuable outcome is a reliable lower-bound stiffness trend engineers can design against.

    Assumption examined · A base fixity test measures an exact stiffness property of the connection rather than a variable system response that must be bounded.

    Original on LinkedIn

  • Article · · Edward Choi

    When Equations Fail: How Market Benchmarks Succeed

    Describes why welded wire mesh under localized load resists closed-form design methods, and how an energy-absorption benchmark — area under the load-displacement curve to a fixed 1-inch displacement — captures durability without fragile assumptions, letting market competition drive improvement.

    Assumption examined · Welded wire mesh behavior under localized load can be honestly described by a closed-form equation suitable for design.

    Original on LinkedIn

  • Article · · Edward Choi

    Are We Penalizing Modern Steel? Normalize the Q Before Design

    Argues that the dimensionless Q from stub-column testing is not design-ready because it embeds the tested material state, and proposes a Design Alignment Ratio R that normalizes test evidence to the design yield strength basis, citing AISI S100 K2.2.2 precedent and Eurocode philosophy.

    Assumption examined · A dimensionless Q from stub-column testing can be applied directly in design regardless of the difference between tested and specified yield strength.

    Original on LinkedIn

  • Article · · Edward Choi

    Where Stiffness Really Comes From: Follow the Contact, Not the Equation

    Argues that stiffness in riveted beam-to-column rack connections originates at the contact elements — hole bearing, rivet bending and clip deformation — rather than in the section properties that global equations describe. Ranks the contributors: contact first, connector geometry second, column section third, beam section least.

    Assumption examined · That beam-to-column connection stiffness is governed by the section properties of the beam and column.

    Original on LinkedIn

  • Article · · Edward Choi

    Higher Strength, Lower Q? What Stub-Column Tests Are Quietly Revealing About Cold-Formed Steel

    Reports stub-column comparisons in which a higher-strength steel produced a lower Q than a lower-strength steel in the same upright geometry, and offers a mechanics-based explanation: steel strengthened before forming has less capacity to redistribute strain around perforations, so local instability caps the peak load while the yield strength in the denominator rises. Presented as a repeated observation and a hypothesis for controlled testing, not a universal rule.

    Assumption examined · That higher steel yield strength produces proportionally higher column capacity, and a similar Q.

    Original on LinkedIn

  • Article · · Edward Choi

    Why HSLAS Steel Should Not Receive Cold-Work Strength Increases

    Argues that cold-work strength increases should not be applied to high-strength low-alloy steel (HSLAS) grades: their strength is produced at the mill by microalloying and controlled rolling, while the AISI S100 cold-work provisions are based on virgin steel properties. Recommends using the specified minimum yield strength and establishing any higher capacity by test.

    Assumption examined · That any cold-formed section qualifies for a cold-work yield-strength increase, whatever the steel grade.

    Original on LinkedIn

  • Article · · Edward Choi

    Why Connection Tests Are Required: When the Same Energy Tells Two Different Stories

    Uses two moment–rotation curves that absorb similar energy but show different stiffness to explain why beam-to-column connection behavior is established by test: bearing, slip, seating and strain hardening are sequence-dependent, and calculations and simulations are only as good as the test-calibrated inputs behind them. Argues that a change in steel source, specification or forming process is a reason to retest.

    Assumption examined · That a connection's stiffness and capacity can be predicted by calculation or simulation without test-calibrated inputs, and carry over unchanged between production batches.

    Original on LinkedIn

  • Article · · Edward Choi

    Lift Table Safety Starts with the Test: What We've Learned from Real-World Design Checks

    Lessons from lift-table testing to ANSI MH29.1: a locking-tooth profile that slipped under concentrated load, wheel ratings that limited the working load below the frame's capacity, missing lift stops, and edge deflection and creep checked against the standard's limits. The common point is that assembled behavior depends on details a calculation or CAD model does not show.

    Assumption examined · That a lift table design that checks out in calculation and CAD will behave the same way as an assembled product under load.

    Original on LinkedIn

  • Article · · Edward Choi

    When Repetition Feels Like Truth: The Illusory Truth Effect in Rack Design

    Examines how the illusory truth effect lets repeated claims harden into accepted fact in rack design, using the commonly quoted Q values (0.90 for 14Ga, 0.95 for 13Ga) as the example: widely repeated and applied, but rarely traced back to the basis they came from. Also unpacks two echoed claims about static capacity tables and the relevance of Q after second-order effects.

    Assumption examined · Commonly repeated Q values, such as 0.90 for 14Ga and 0.95 for 13Ga, apply to any section without checking the basis they came from.

    Original on LinkedIn

  • Technical explainer · · Edward Choi

    Rack Design's Quiet Revolution: From Anet,min to Anet,g

    Explains the ANSI MH16.1-2021 shift from minimum net area (Anet,min) to global buckling area (Anet,g) in rack column design — from designing for the weakest perforated section to modeling integrated stiffness over the full perforation pattern.

    Assumption examined · That column strength is governed by the minimum net section at a single perforation, rather than the integrated stiffness of the full perforation pattern.

  • Technical explainer · · Edward Choi

    Clarifying Structural Loading Protocols: Why the Nuance Matters

    Defines four loading protocols for beam-to-column connection testing — monotonic, repeated monotonic, unidirectional cyclic, and bi-directional cyclic — what each reveals (peak capacity, bolt slip, stiffness degradation, energy dissipation), and why choosing the wrong protocol misrepresents connection performance.

    Assumption examined · That monotonic and cyclic are interchangeable labels — the loading protocol chosen determines which connection behaviors a test can actually reveal.

    Original on LinkedIn

  • Article · · Edward Choi

    What Defines a Manufacturer? A Framework for Qualification and Accountability

    A framework for what qualifies a company as a manufacturer — engineering validation, design authority, quality systems, and legal accountability — distinguishing true manufacturers from distributors and resellers in an era of outsourced and white-labeled production.

    Assumption examined · That owning machinery or a brand is what makes a company a manufacturer — the piece argues qualification rests on design control, validation, and legal accountability.

    Original on LinkedIn

  • Article · · Edward Choi

    Are We Penalizing Modern Steel? Rethinking Q-Factor Corrections in Rack Design

    Argues that applying stub column Q-factors directly in design — without correcting for the gap between tested and specified yield strength — penalizes modern steel, proposes Qdesign = Qtest x (Fy,test / Fy,design), and cites the AISI S100 flat-yield adjustment as precedent.

    Assumption examined · That a dimensionless Q-factor can be applied in design without accounting for the yield strength embedded in the test that produced it.

    Original on LinkedIn

  • Technical explainer · · Edward Choi

    Proof-Load Test: Anchor vs. Slab Uplift — Start with WHY, Not WHAT

    Distinguishes anchor proof-load tests (installation quality) from slab uplift proof-load tests (structural capacity), notes that torque checks only confirm engagement rather than strength, and names the three slab-related tests industry terminology often conflates: concrete core strength, slab uplift, and downforce puncture.

    Assumption examined · That testing anchors and testing slab capacity answer the same question — each validates a different assumption behind the installation.

    Original on LinkedIn

  • Article · · Edward Choi

    From Outskirts to City: Why Outsourcing Validation Is the Right Direction

    Compares in-house validation testing with using an accredited laboratory, through the analogy of self-sufficient living outside a city versus relying on shared infrastructure. Argues that manufacturers tend to count the expense of outside testing but not the opportunity cost of engineers' time spent validating rather than designing.

    Assumption examined · That in-house testing is the lower-cost path once the equipment is bought — a comparison that leaves out engineering time, calibration and upkeep.

    Original on LinkedIn

  • Article · · Edward Choi

    Reducing Hidden Costs in Structural Testing: A Guidance for International Material Imports

    Explains how international clients shipping steel components for destructive testing can avoid unnecessary customs duties and delays: classify under HTSUS Subheading 9811.00.60, label shipments as test material not for resale, and work with brokers familiar with lab-only imports.

    Original on LinkedIn

  • Technical explainer · · Edward Choi

    Why Higher-Strength Steel Doesn't Always Deliver Proportionate Gains in Axial Capacity?

    Explains why stronger steel does not proportionally raise rack column capacity: stub column tests reveal a geometry-governed ceiling load driven by perforations and local buckling, expressed through the Q-factor, with diminishing returns as Q approaches 0.5.

    Assumption examined · That increasing steel yield strength proportionally increases a rack column's usable axial capacity.

    Original on LinkedIn

Technical notes

Short published notes

Originally published on LinkedIn; collected here as the archive of record.

TitlePublishedSummary
Beyond Linear Interpolation (and Why We Pretend It Doesn't Exist)Original on LinkedInMakes explicit how multi-variable load tables are constructed: theory establishes the trend, test results anchor and calibrate the surface, and nearby configurations are estimated with tested, interpolated, and extrapolated points clearly identified — a practice the author informally calls 3-D interpolation.
Do Anchors Actually Participate in Compression-Only Base Fixity Testing?Original on LinkedInPoses a screening hypothesis: in compression-dominated base fixity tests where rigid-body slip and rotation are demonstrably controlled, the measured moment-rotation response is governed by plate bending, wall deformation, and contact mechanics rather than anchor tension, so unanchored setups may deliver the same lower-bound stiffness trend at lower cost.
Why §13.5.5 Stiffness Results Scatter — and Why That's Not a Testing ProblemOriginal on LinkedInExplains why Kconn values derived from peak sustained cycles scatter for boltless rack connections — direction-dependent engagement, nonlinear seating, and slip — while the energy-averaged linearized spring constant F stays within expected repeatability, and why LH/RH and CW/CCW interpretations add clarity beyond the required Section 13.5.5 reduction.
When 32.2 Made Me Respect Units — and Why Dimensionless Ratios Aren't MagicOriginal on LinkedInA reflection on the lbf/lbm/slug distinction and the 32.174 ft/s2 constant, arguing that dimensionless ratios like KL/r hide but do not erase the physics, with three guardrails for keeping unitless numbers honest.
Recognizing the Right Way to Interpret Connector StiffnessOriginal on LinkedInExplains that rack connection stiffness is defined per connector rather than by summing left-hand and right-hand contributions, distinguishing discontinuous connectors (measured stiffness divided by two) from continuous connectors, and noting the 2023 shift to direction-specific (CW/CCW) evaluation.
Rack Connection Stiffness: The Shift from F to KconnShort post contrasting the traditional linearized spring constant F (historically reduced by 2/3 for beam analysis) with Kconn, defined at 80% of connection strength per ANSI MH16.1-2023 and usable in design without an extra reduction factor.
No Free Lunch in Column Design: Why Bigger Isn't Always BetterOriginal on LinkedInA short comparison of two steel column profiles (4 x 2.75 in. 14-gauge vs. 3 x 3 in. 12-gauge) showing why size and gauge alone don't determine performance — bending resistance, torsional stability, local buckling, and impact resilience all trade off.
Rethinking Diagonal Bracing: A Modular Tension-Based ApproachOriginal on LinkedInProposes tensioned cables as a field-adjustable alternative to pre-cut bolted diagonal bracing in rack frames — fewer SKUs, simpler installation, comparable unit cost — and asks why economic inertia, not technical infeasibility, stalls such ideas.

Full-length articles are in the Knowledge Center.

Reading because an assumption of yours is in here?

That’s the point of publishing. If a piece names the uncertainty you’re carrying, testing can resolve it.

Request testing