Why HSLAS Steel Should Not Receive Cold-Work Strength Increases

By Originally published

Publication record

Argues that cold-work strength increases should not be applied to high-strength low-alloy steel (HSLAS) grades: their strength is produced at the mill by microalloying and controlled rolling, while the AISI S100 cold-work provisions are based on virgin steel properties. Recommends using the specified minimum yield strength and establishing any higher capacity by test.

Assumption examined · That any cold-formed section qualifies for a cold-work yield-strength increase, whatever the steel grade.